Troubleshooting (Continued)

Problem

Check

Action

Clock does not run
(continued).

— pins in program dial. If pins are

not completely seated in
program dial, jamming with
index wheel may occur.

Push down on pins to make sure they are
completely seated in program dial.

Clock loses time.

— power. May be interrupted.

Make sure power is On. Reset clock.

— high limit control. If clock is

powered through system
transformer, power to clock
and equipment may be off on
safety.

Wire separate transformer to power clock, or
install backup batteries as shown in Fig. 2.

— filter. May be clogged. Safety

limit on equipment may cut off
power to system.

Replace filter and reset clock.