69-0628B—1

Problem

Check

Action

No heat.

— system switch. May be in OFF

or COOL position. 1

Move system switch to HEAT position.

— fuse or circuit breaker.

If blown or tripped, replace fuse or reset breaker.

— furnace power switch. May be

Off.

Move switch to ON .

— pilot flame. May be out.

Relight pilot flame per furnace manufacturer’s
instructions.

— thermostat connections.

Turn Off power to furnace. Check for correct
terminal hookups. Repair any frayed or broken
wires. Firmly tighten all terminal screws. Turn
power On.

1

Applicable to heating-cooling subbase only.

Continued

Troubleshooting

Your Honeywell thermostat requires little or no attention. Most problems can generally be traced

to the following: