1. selecting equipment, 2. grounding generator to truck or trailer frame – Hobart Welding Products OM-477 Manuel d'utilisation

Page 42

Advertising
background image

OM-477 Page 38

SECTION 9 – AUXILIARY POWER GUIDELINES

9-1.

Selecting Equipment

aux_pwr 2/99 – Ref. ST-159 730 / ST-800 577

1

Auxiliary Power Receptacles
– Neutral Bonded To Frame

2

3-Prong Plug From Case
Grounded Equipment

3

2-Prong Plug From Double
Insulated Equipment

OR

2

Be sure equipment
has this symbol
and/or wording.

3

1

9-2.

Grounding Generator To Truck Or Trailer Frame

S-0854

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding
Terminal

4

Grounding Cable

Use #10 AWG or larger insulated
copper wire.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-pro-
tected extension cord.

OR

1

2

Electrically bond generator
frame to vehicle frame by
metal-to-metal contact.

GND/PE

2

3

4

Advertising