4. duty cycle and overheating, 5. ac auxiliary power – Hobart Welding Products OM-477 Manuel d'utilisation

Page 15

Advertising
background image

OM-477 Page 11

6 Minutes Welding

4 Minutes Resting

Continuous Welding

3-4.

Duty Cycle And Overheating

rduty1 5/95 – SB-111 076-A

Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.

Y

Exceeding duty cycle can
damage unit and void
warranty.

60% Duty Cycle At 350 Amperes

100% Duty Cycle At 300 Amperes

3-5.

AC Auxiliary Power

The ac power curve shows the aux-
iliary power in amperes available at
the 120 and 240 volt receptacles.

rsb3.1 2/92 – ST-109 365-C