7-1.

Routine Maintenance

Recycle

engine

fluids.

Y

Stop engine before maintaining.

.

See also Engine Manual and Maintenance
Label. Service engine more often if used in
severe conditions.

*

To be done by Factory Authorized Service
Agent.

8 h

Wipe up spills.

Check fluid levels.
See Section 4-4.

OIL

Full

50 h

Clean air filter.
See Section 7-3.

Clean and tighten
weld terminals.

100 h

Change oil. See
Section 7-5.

Change oil filter.
See Section 7-5.

Replace fuel filter.
See Section 7-6.

Clean and tighten battery
connections.

200 h

250 h

Replace
unreadable
labels.

Check spark
plugs.

Check and clean
spark arrestor.
See Section 7-7.

500 h

Check valve clearance.*

Repair or replace
cracked cables.

1000 h

Blow out or
vacuum inside.
During heavy
service, clean
monthly.

Check
belt
tension.

Or

1/2 in.

(13 mm)

Service welding generator

brushes and slip rings.

Service more often in dirty

conditions.*