7. volt-ampere curves – Hobart Welding Products OM-477 Manuel d'utilisation

Page 17

Advertising
background image

OM-477 Page 13

3-7.

Volt-Ampere Curves

The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.

rsb13.1 12/94 – ST-184 477-A / ST-184 475-A / ST-184 480-A

A. CC/DC (Standard)

B. CC/AC (Models with Optional Polarity/AC Selector Switch)

C. CV/DC (Models with Optional CV-3 Module)

0

20

40

60

80

100

0

100

200

300

400

500

600

700

AC Amperes

AC V

olts

0

20

40

60

80

100

0

100

200

300

400

500

600

700

DC Amperes

DC V

olts

Ranges: 190–Max

110–270

85–210
55–110

Min–65