18
Opening width
W
30" Model
30" (762mm)
Exhaust Hood Installation
The bottom of the hood should be 30" min. to 36" above the countertop. This would typically result in the bottom of the
hood being 66" to 72" above the floor. These dimensions provide safe and efficient operation of the hood.
After Installation:
1. Check ignition of cooktop burners.
2. Check the air shutter adjustment – sharp blue flame, with no yellow tipping or lifting flames.
3. Check ignition of oven burner.
4. Visually check tubular burner (oven burner) re-ignition to be sure both rows of burner ports are relighting each time.
5. Check for gas leaks at all gas connections (using a gas detector, never a flame).
Front edge of the
range side panel
forward from
cabinet
To countertops
below cooktop
and at the
range back