Warning – Forno Lazio 30 Inch Freestanding Dual Fuel Range User Manual Manuel d'utilisation

Page 16

Advertising
background image

14

WARNING

The plug should be an electric supply cord set 4 wires type with ring terminals (L1, L2, N, Ground) suitable for range use

UL/CSA listed type SRDT/DRT 2X8AWG (L1, L2) + 2X10AWG (N,G) rated 120V/240V, AC 60HZ plug type; cable length
1.5m; in case the supply cord set must be replaced, it shall be replaced with an identical set having the

same technical specs and carefully following the instructions and diagrams from the last page of this manual.

Step 3: Connecting the electric supply cord set 4 wires with ring terminal (L1, L2, N, ground)

1. Connect the L1 receptacle terminal to the incoming electrical supply wire (L1-hot wire).
2. Connect the L2 receptacle terminal to the incoming electrical supply wire (L2-hot wire).
3. Connect the NEUTRAL receptacle terminal to the incoming NEUTRAL electrical supply wire(N).
4. Connect the GROUND receptacle terminal to the incoming GROUND electrical supply wire (E).


Step 4: Fix the screw and put back the cover

Advertising