Alternate installations for close clearances, Special provisions for mobile home installations, Determine vent length – Kenmore ELITE HE4 110.C8586 Manuel d'utilisation

Page 9: Awarning

Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Advertising
background image

This dryer can be converted to exhaust out the right side, left

side, or through the bottom. Contact your local dealer to have the
dryer convered.

Optional exhaust installations

AWARNING

M

Fire Hazard

Cover unused exhaust holes with one of the
following kits:

279818 (white)

279915 (graphite)

279925 (biscuit)

280102 (pacific blue)

280103 (champagne)

280104(sedona)

Contact your local dealer.

Failure to follow these instructions can result in death,

fire, electrical shock, or serious injury.

A. Standard rear offset exhaust installation

B. Left or right side exhaust installation
C. Bottom exhaust installation (Not an option

with pedestal installations.)

Alternate installations for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

A. Over-The-Top installation (also available with one

offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please cal 11-800-4-MY-HOME® (1-800-469-4663).

■ Over-The-Top Installation:

Part Number 26-49900

■ Periscope Installation (For use with dryer vent to wall vent

mismatch):

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch

Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent length
1. Select the route that will provide the straightest and most

direct path outdoors. Plan the installation to use the fewest
number of elbows and turns. When using elbows or making
turns, allow as much room as possible. Bend vent gradually
to avoid kinking. Avoid 90° turns when possible.

Determine vent length

The maximum length of the exhaust system depends upon:

■ The type of vent (rigid metal or flexible metal).

■ The number of elbows used.

■ Type of hood.

Recommended hood styles are shown here.

A. Louvered hood style
B. Box hood style

Advertising