Mobile home - additional installation requirements, It is your responsibility, Awarning – Kenmore ELITE HE4 110.C8586 Manuel d'utilisation

Page 7

Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Advertising
background image

Closet installation - Dryer only

(7.6 cm)

J7.6 cm)

AWARNING

'ii

Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

A. Side view - closet or confined area
B. Closet door with vents

Recessed or closet installation - Dryer on pedestal

71

B

A. Recessed area
B. Side view - closet or confined area

Mobile home - additional installation requirements

This dryer is suitable for mobile home installations.
The installation must conform to the Canadian Manufactured

Home Standard, CAN/CSA Z240 MH.

Mobile home installations require:

■ Metal exhaust system hardware which is available for

purchase from your local Sears store or Sears Service Center.

■ Special provisions must be made in mobile homes to

introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.

It is your responsibility

■ To contact a qualified electrical installer.

■ To be sure that the electrical connection is adequate and in

conformance with the Canadian Electrical Code, C22.1 -latest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3
Canada.

■ To supply the required 4 wire, single phase, 115/230-volt,

60-Hz., AC-only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.

■ This dryer is equipped with a CSA International Certified

Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure
wall receptacle is within reach of dryer’s final location.

4-wire receptacle 14-30R

m Do not use an extension cord.

If using a replacement power supply cord, it is recommended

that you use Power Supply Cord Replacement Part Number
3394208. For further information, please call 1-800-4-MY-HOMP