Dryer dimensions, You will need, Installation clearances – Kenmore ELITE HE4 110.C8586 Manuel d'utilisation

Page 6: Ikwarning

Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Advertising
background image

ikWARNING

J

Dryer Dimensions

U/

Explosion Hazard

Keep flammable materials and vapors, such as

gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor

for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need
■ A location that allows for proper exhaust installation. See

“Venting Requirements.”

■ A separate 30-amp circuit,

■ A grounded electrical outlet located within 2 ft (61 cm) of

either side of the dryer. See “Electrical Requirements.”

■ A sturdy floor to support the total dryer weight of 200 lbs

(90.7 kg). The combined weight of a companion appliance
should also be considered.

■ A level floor with a maximum slope of 1" (2.5 cm) under entire

dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part Number 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.

■ For a garage installation, you will need to place the dryer at

least 18" (46 cm) above the floor. If using a pedestal, you will
need an additional 6" (15.24 cm).

Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to
open fully.

*Most installations require a minimum 5V2 (14 cm) clearance

behind the dryer for fhe exhaust vent with elbow. See “Venting
Requirements.”

Minimum installation spacing for recessed area, custom
undercounter or closet installation

The following dimensions shown are for fhe minimum spacing
allowed.

■ Additional spacing should be considered for ease of

installation and servicing.

■ Additional clearances might be required for wall, door and

floor moldings.

■ Additional spacing of 1" (2.5 cm) on all sides of the dryer is

recommended to reduce noise transfer.

■ For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.
Fouvered doors with equivalent ventilation openings are
acceptable.

■ Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer oniy