( Power Management System)

This nrxjnitor meets VESA (Video Electronics Standards Association) DPMS (Display Power

Management Signaling) standards. In order for the monitor’s power saving feature to func­

tion, the video board or computer must also meet VESA» DPMS™ standards.

State

Power LED

Power

Recovery time

On

Green

Normal

Not Applicable

Standby

Amber

< 15 Watts

< 3 seconds

Suspend

Amber

< 15 Watts

< 3 seconds

Off

Amber

< 5 Wafts

< 20 seconds

Note:* The Power Management System "Off" State is different from the "Off" stste of the

Power Switch. When The Power Switch is "Off" the Power LED is dark.

The monitor goes into various power saving stages depending on the incoming video

signal as shown in the following table.

State

Horizontal Sync

Vertical Sync

On

Pulses

Pulses

Standby

No Pulses

Pulses

Suspend

Pulses

No Pulses

Off

No Pulses

No Pulses

The monitor automatically goes through the PMS (Power Management System) states
when there are r« Horizontal and/or Vertical sync pulses. To release the nwnitor from a

PMS state, press any key on the computer keyboard.