Tweco 150XL CE PAK Master Manuel d'utilisation

Page 42

Advertising
background image

SERVICE

5-6

Manual 0-2826

H. AC POWER LED indicator ON; Fans operate; No

gas flow

1. Gas not connected or pressure too low

a. Check source for at least 100-125 psi (68.9- 86.2

bar).

2. Faulty components in unit

a. Return for repair or have qualified technician

repair per Service Manual.

I.

Torch cuts but not adequately

1. Current set too low

a. Increase current setting.

2. Torch is being moved too fast across workpiece

a. Reduce cutting speed (refer to Instruction

Manual supplied with torch).

3. Excessive oil or moisture in torch

a. Hold torch 1/8 inch (3 mm) from clean surface

while purging and observe oil or moisture
buildup (do not activate torch)

4. Defective torch parts

a. Replace defective parts.

J.

GAS LED indicator OFF

1. Gas pressure set too low

a. Adjust pressure

2. Faulty power supply

a. Return for repair or have qualified technician

repair per Service Manual.

3. No coolant flow.

a. Return for repair or have qualified technician

repair per Service Manual.

K. GAS LED indicator OFF, plasma and/or secondary

gas does not flow

1. Low plasma pressure

a. Check plasma pressure

2. Secondary supply turned OFF (or cylinder empty)

a. Check secondary supply

3. Blocked torch

a. Check torch parts.

4. Faulty power supply

a. Return for repair or have qualified technician

repair per Service Manual.

L. GAS LED Indicator flashing ON and OFF

1. Air in coolant lines

a. Check for proper coolant level at rear panel gauge

b. Run pump for ten minutes to purge air from the

coolant lines before using the system.

M. Leaking torch connection

1. Loose torch connection

a. Check connection making sure connector is fully

seated.

N. Weak or sputtering pilot; CD stays on during pilot

1. Plasma gas pressure too high

a. Adjust pressure

2. Low OCV (normal 290-350 VDC) caused by improper

input voltage selection

a. Check input voltage connections

3. Faulty power supply

a. Return for repair or have qualified technician

repair per Service Manual.

O. Pilot arc ON; No main arc transfer (torch brought

within range of work)

1. Work cable not connected

a. Connect work cable securely

2. Faulty power supply

a. Return for repair or have qualified technician

repair per Service Manual.

P. AC LED indicator ON; GAS LED Indicator light

on when torch switch pressed; DC LED Indicator
light blinks

1. Shorted torch.

a. Return for repair or have qualified technician

repair per Service Manual.

2. Faulty power supply.

a. Return for repair or have qualified technician

repair per Service Manual.

Advertising