INSTALLATION

3-4

Manual 0-2826

C. Using High Pressure Gas Cylinders Only

NOTES

Refer to the manufacturer’s specifications for in-
stallation and maintenance procedures. Refer to
sales literature for a listing of available high-pres-
sure regulators and accessories.

Do not use an air line filter with high pressure regu-
lators.

1. Examine the cylinder valves to be sure they are clean

and free of oil, grease or any foreign material. Mo-
mentarily open each cylinder valve to blow out any
dust which may be present.

WARNING

Do not stand in front of valve outlet when open-
ing.

2. Each cylinder must be equipped with an adjustable

high-pressure regulator capable of outlet pressures up
to 100 psi (6.9 bar) maximum and flows of up to 400
scfh (188.7 lpm).

CAUTION

Pressure should be set at 100 psi (6.9 bar) at the
high pressure gas cylinder regulator.

3. When using gas cylinders as the plasma and second-

ary gas supplies the connections will depend on the
number of cylinders used. Refer to one of the follow-
ing procedures and make the gas connections.

Using Single Gas Cylinder for Plasma and Sec-
ondary Gas

If the Plasma and Secondary gas source are to be
the same and will use the same high pressure cyl-
inder, connect the gas regulator supply hose from
the gas cylinder to the Power Supply as follows:

a. Remove the Plasma and Secondary Hoses from the

Inert-B Fitting at the Plasma and Secondary Regula-
tor/Filter Assemblies of the Power Supply.

b. Remove the factory installed Two Stage Air Line

Filter Assembly and gas supply hoses from the
Power Supply.

c. On the Two Stage Air Line Filter remove the two

hoses and the T-Fitting at the output port (OUT).

d. Reconnect the Plasma Hose to the Plasma Regula-

tor/Filter Assembly Inert-B Fitting.

e. Reconnect the Secondary Hose to the Secodary

Regulator/Filter Assembly Inert-B Fitting.

f. Install a 1/4 NPT-Insert B (right-hand) Adapter

Fitting (see NOTE) into the end of the T-Fit-
ting.

NOTE

Adapter Fitting must be supplied by the customer.

g. Connect the customer supplied gas regulator

supply hose directly to the Adapter Fitting.

Plasma Gas

Supply Hose

Plasma Air

Regulator Assembly

A-02877

Barbed

Fitting

T Fitting

Inert B Fitting

Secondary Air

Regulator Assembly

Secondary Gas

Supply Hose

Inert B Fitting

Gas Supply Hose

Hose Clamp

Figure 3-3 Connection Using Single Gas Cylinder

Using Seperate Gas Cylinders for Plasma and
Secondary Gas

If the Plasma and Secondary gases will be differ-
ent or two separate high pressure cylinders are to
be used, connect the gas regulator supply hoses
to the Power Supply as follows:

a. Remove the Plasma and Secondary Hoses from the

Inert-B Fitting at the Plasma and Secondary Regula-
tor/Filter Assemblies of the Power Supply.

b. Connect the customer supplied gas cylinder supply

hose from the plasma gas source directly to the in-
put fitting at the PLASMA air regulator of the Power
Supply.