6 SLC 500 BASIC and BASIC-T Modules

Publication 1746-IN009B-EN-P - August 2005

Figure 1 Communication Ports and LED Indicators

LED

Color

Status

Indication

ACT

Green

ON

The module is receiving power from the backplane and is
executing BASIC code.

Flashing

The module is in Command mode.

OFF

The module is not receiving power from the backplane. A fault
condition exists.

485

Green

ON

Port DH485 on the module is active for communication.

OFF

Port DH485 on the module is not active for communication.

PRT1

Green

Flashing

Port PRT1 on the module is transmitting or receiving signals.

OFF

Port PRT1 on the module is not transmitting or receiving signals.

PRT2

Green

Flashing

Port PRT2 on the module is transmitting or receiving signals.

OFF

Port PRT2 on the module is not transmitting or receiving signals.

FAULT

Red

ON

A system problem was detected during background diagnostics.
Contact your local Allen-Bradley representative.

OFF

No system problems are detected during background diagnostics.

BA LOW

Red

ON

The voltage of the battery that backs up RAM is low. A new
battery is needed.

OFF

The voltage of the battery that backs up RAM is at an acceptable
level.

LED1

Amber

ON

User definable. LED activated through the user program.

OFF

User definable. LED de-activated through the user program.

LED2

Amber

ON

User definable. LED activated through the user program.

OFF

User definable. LED de-activated through the user program.

ACT

485

PR T1

PR T2

FAULT

BA LOW

LED1

LED2

PRT1

5
4
3
2
1

9
8
7
6

PRT2

5
4
3
2
1

9
8
7
6

DH485

BASIC

BASIC

LEDs