16 SLC 500 BASIC and BASIC-T Modules

Publication 1746-IN009B-EN-P - August 2005

Figure 8 RS-232/423 Wiring Diagram - 1746-BAS Module or 1746-BAS-T Module
to a Modem (Hardware Handshaking Enabled)

Figure 9 RS-232/423 Wiring Diagram - 1746-BAS Module or 1746-BAS-T Module
to DTE Device (Hardware Handshaking Disabled)

IMPORTANT

For DCE devices other than modems, connect the DSR of the
module with the DSR of the device. The CD signal of the device
(other than a modem) is not used.

N.C.

1

RXD

2

TXD

3

DTR

4

COM

5

DSR

6

RTS

7

CTS

8

N.C.

9

CD

RXD

TXD

DTR

COM

DSR

RTS

CTS

RI

8

3

2

20

7

6

4

5

22

1

2

3

4

5

6

7

8

9

BASIC DTE

DCE

9-Pin

25-Pin

N.C.

1

RXD

2

TXD

3

DTR

4

COM

5

DSR

6

RTS

7

CTS

8

N.C.

9

DCD

TXD

RSD

DSR

COM

DTR

CTS

RTS

GND

8

2

3

6

7

20

5

4

1

1

3

2

6

5

4

8

7

(1)

(3)

(2)

(2)

(2)

(2)

BASIC DTE

DCE

9-Pin

25-Pin

(1) Connect to the shield of the cable.

(2) Jumpers are only needed if you cannot disable the hardware handshaking on the port.

(3) This is a N.C. for the 1747-KE module, 1746-BAS module, or 1746-BAS-T module.