10 SLC 500 BASIC and BASIC-T Modules

Publication 1746-IN009B-EN-P - August 2005

Figure 5 Jumper JW3 Pin Assignments and Settings

Module Jumper JW4

Use jumper JW4 to select one of the following configurations for the module ports.

• PRT1 Port = Program port with default communication settings

PRT2 Port = ASCII interface port

DH485 Port = Run time DH485 operation only

• PRT1 Port = ASCII interface port

PRT2 Port = ASCII interface port

DH485 Port = Program port with DH485 protocol

• PRT1 Port = Program port with programmed communication settings

PRT2 Port = ASCII interface port

DH485 Port = Run time DH485 operation only

• PRT1 Port = Program port with programmed communication settings

PRT2 Port = DF1 protocol

DH485 Port = Disabled

IMPORTANT

The first setting shown in Figure 6 is the default configuration.
When the jumper is set in this position, the module always
powers up in Command mode at 1200 bps, no parity, 8 data bits,
and 1 stop bit.

2

4

6

1 3

5

Pin
Assignments

1747-M4 UVPROM

(1)

(1)

This memory module is no longer available for sale from Rockwell Automation. Existing 1747-M3 and
1747-M4 memory modules are compatible with the 1746-BAS module and 1746-BAS-T module.

1747-M1 EEPROM

1747-M2 EEPROM

1747-M3 UVPROM

(1)

1771-DBMEM1 EEPROM

1771-DBMEM2 EEPROM

(Shipped Configuration)