Installation continued – Garland HEEGM XX CL HIGH EFFICIENCY RADIANT CHAR-BROILER Manuel d'utilisation

Page 7

Advertising
background image

Part # 4530868 (04/25/12)

Page 7

INSTALLATION Continued

Air Supply and Ventilation

VENTILATION REQUIREMENTS MAY BE SUBJECT TO LOCAL

BUILDING AND FIRE CODES. CONSULT LOCAL AUTHORITIES

HAVING JURISDICTION.

1. For any commercial cooking appliance, means must

be provided to exhaust combustion waste products to

the outside of the building. This is especially important

for broilers, since they generate substantial amounts of

smoke when in operation.

2. A properly designed ventilating canopy should be used

for this appliance, which extends at least 6” (152mm)

beyond each side of the appliance (except against the

wall if the canopy is a wall installation) and is equipped

with filters and drip troughs.

3. Air movement should be checked during installation.

There must be adequate air intake into the building

to compensate for the amount of air removed by the

ventilation system. Without a proper balance, abnormal

atmospheric pressure will occur, affecting burner and

appliance performance. If air movement is a concern,

adjustments should be made to correct the problem by a

qualified technician.

HAVING DIFFICULTY OPENING DOORS THAT EXIT THE

BUILDING, IS AN INDICATION THAT THE BUILDING HAS A

PROBLEM WITH AIR MOVEMENT.

4. Do not permit fans to blow directly at the appliance and

avoid opening windows behind or beside the appliance.

This can create air cross-currents and/or excessive drafts

that interfere with the operation of the unit.

Electrical Connection

DISCONNECT THE POWER SUPPLY BEFORE SERVICING.

1. Standard units are supplied with a Nema 5-15P power

cord with appropriate strain relief. This will require a

suitable 120V 15Amp 60Hz outlet in close proximity to

the appliance. Consult a certified electrician if you have

concern about the suitability of the outlet.

DO NOT USE AN EXTENSION CORD TO CONNECT THIS UNIT

TO A POWER SUPPLY. DO NOT USE THIS APPLIANCE IF THE

POWER CORD IS DAMAGED. DO NOT ATTEMPT TO REPAIR A

DAMAGED POWER CORD. TAKE CARE NOT TO EXPOSE THE

POWER CORD TO HEAT OR SHARP EDGES.

2. Units supplied without a cord are intended for use with a

220-240V (LINE TO LINE) single phase power supply. The

appliance must be fitted with an appropriate power cord

2. The unit is designed to sit flush on a counter, stand or

refrigerated base. Leveling of the unit is done through

adjustment of the stand casters, refrigerated base legs/

casters or using shims for countertop installation.

IT IS IMPERATIVE THAT THE UNIT IS PROPERLY LEVELED

DURING INSTALLATION TO ENSURE OPTIMAL PERFORMANCE

OF THE PRODUCT.

3. To comply with NSF requirements, the unit should be

sealed to the mounting surface with silicone. If possible,

apply silicone to the underside of both leg channels

and then put the unit in place on the mounting surface.

Otherwise, apply silicone to the surface first and then put

the unit on the surface, placing the leg channels on the

pre-applied silicone. Avoid sealing lower stainless steel

panels to the surface, as these may need to be removed

for service.

4. Position the appliance in an area that is free and clear of

all combustibles. This unit is for use in non-combustible

locations only.

5. For service, this unit may need to be accessed from the

side. An adequate service clearance should be provided

in front of the unit to enable the unit to be brought

forward for access to serviceable components. Keep this

in mind when determining the installation location.

Optional Stand

STANDS SPECIFICALLY DESIGNED TO ACCOMMODATE

THESE UNITS ARE AVAILABLE FOR PURCHASE. USE THE

APPROPRIATE STAND FOR THE SIZE OF UNIT. FOR YOUR

SAFETY, BE SURE TO SECURE THE UNIT TO THE STAND WITH 4

SCREWS, AS SHOWN BELOW.

DRIVE SCREWS UP
THROUGH STAND AND
INTO UNIT LEG CHANNELS
(ONE PER CORNER)

STAND ASSEMBLY INSTRUCTIONS ARE PROVIDED WITH EACH

STAND.

Advertising