Equipment sizing – Aquascape AquaForce (99443, 99444 & 99445) Manuel d'utilisation

Page 4

Advertising
background image

) equipment Sizing

3.1 Sizing your Aquascape™ AquaForce™ Pump to your pond.
• Determine the volume of your pond. If you are unsure of your total pond volume, it can be

calculated by measuring in feet the average Length of your pond, the average Width, and

the average Depth. Multiply these measurements – Length X Width X Depth – this will

give you the average volume of the pond in cubic feet. Since there are 7.48 US Gallons per

cubic foot, we can multiply Length X Width X Depth X 7.48. Example – for a pond that is

8(L) X 5(W) X 2(D) = 80 cubic feet X 7.48 = 598.4 US Gallons.

• You want to ensure that the total volume of pond water in your pond is turned over at least

once every two hours. That means in a 1500 gallon pond, the minimum size pump you

could choose would be the Aquascape™ AquaForce™ Pump 1000.

• You also want to ensure that whatever filtration system you are using can handle the

amount of water that the Aquascape™ AquaForce™ Pump model you have chosen

will produce. For example, the Aquascape™ UltraKlean™ 1500 Pressure Filter has a

maximum flow rate of 1500 GPH (Gallons Per Hour). The Aquascape™ AquaForce™

Pump—1000 or Aquascape™ AquaForce™ Pump—1500 may be used.

3.2 Sizing the Tubing to your Aquascape™ AquaForce™ Pump.
• The correct sized tubing is extremely important because of the restrictions encountered

when pumping water through tubing. Tubing that is too small will affect the performance

of your pump. Refer to Table 2 for minimum tubing size. In all cases, it is better to oversize

the tubing for maximum performance.

Table 1


Item
Number


Model
Number


Maximum
Flow Rate

Maximum

Pumping

Height

Power

Consumption

Weight

Max.

Outlet

Size

99443

AF1000

1000 GPH

6’5”

50 watts

5 lbs

1½”

99444

AF1500

1500 GPH

8’

65 watts

5 lbs

1½”

99445

AF2000

2000 GPH

10’

110 watts

5.8 lbs

1½”

Table 

Item Number

Model Number

Maximum
Flow Rate

Minimum
Tubing Size

99443

AF1000

1000 GPH

1 inch

99444

AF1500

1500 GPH

1¼ inch

99445

AF2000

2000 GPH

1½ inch

4

99443 AquaForce Instructions FIN4 4

6/9/06 2:01:59 PM

Advertising