20

Mounting the outdoor sensor (optional)

Mount the sensor vertically on an
exterior wall, at least 6 inches below
any overhang. Choose a location
protected from direct sunlight.

Place sensor securely in bracket,
facing away from wall.

Error codes

8.

Display

Description

LO

The indoor temperature is below 0°C (32°F).

HI

The indoor temperature is above 60°C (140°F).

- -

The temperature reading is currently unavailable or the sensor is defective.

E128

The wireless network setup must be redone.

E129

Attempting to connect incompatible wireless devices.

E130

Invalid address. Call customer assistance.

E134

Low signal strength. Move wireless device to a different location and try again.

E137

Maximum number of devices is exceeded.

E138

Make sure Connected light on EIM is flashing and you are 2+ feet away from EIM.

E152

Incorrect order. Make sure to link EIM to proper thermostat.

69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 20 Wednesday, June 29, 2011 1:15 PM