18

Anti-freeze

When this function is on, the EIM will maintain the room temperature at 13°C (55°F) if it loses
communication with the thermostat or if the thermostat sensor is defective.

To turn off the Anti-freeze protection, proceed as follows:

System test
1)

From the Home screen, press until the setpoint temperature is above the room
ambient temperature by at least 2°. Press Temporaire (temporary).

2)

Wait for Chauffe (heat) to display on the thermostat.

3)

Verify if the heater becomes hot.

4)

Press Annuler (cancel) to return the thermostat to its previous mode.

Leave the protection on unless the EIM is installed in a junction box in a separate room from
the heater.

#

Display

Button

Step

1)

From the installer’s setup

menu, press

as needed to

select Hors-Gel (anti-freeze)
and press Ok.

2)

Press

or

to select Non

(no). Press Ok.

69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 18 Wednesday, June 29, 2011 1:15 PM