Section 3 |

inStALLAtion / enViRonMentS

2. Switch oN the inverter
3. Wait for a few seconds
4. Switch oN the load

Switching OFF

1. Switch off the load connected to the inverter
2. Switch off the inverter

CONNECTING LOADS

1. Make sure that the single load or the combined load requirement of your equipment does not

exceed the inverter’s output rating.

2. Switch off the inverter
3. Switch off the load
4. Plug the cord(s) from the load(s) into the AC receptacle(s) of the inverter
5. Switch on the inverter. Wait for a few seconds
6. The green LeD indicator will be lighted to indicate that the inverter is functioning
7. Switch on the load(s)

The inverter is engineered to be connected directly to standard electrical and electronic equipment in

the manner described above. Do not connect the power inverter to household or RV AC distribution

wiring. Do not connect the power inverter to any AC load circuit in which the Neutral conductor is
connected to Ground (Earth) or to the Negative of the DC (battery) source.

WARNING:

Do not connect

directly to AC distribution wiring. This inverter is NOT grid interactive.

OPERATING ENVIRONMENT

for best operating results, the inverter should be placed on flat surface, such as the ground, car floor, or

other solid surface. The power cord allows easy positioning of the inverter. The inverter should only be

used in locations that meet the following criteria:

DRY

Do not allow water and/or other liquids to come into contact with the power inverter. In all marine

applications, do not install the inverter below or near the waterline and keep the inverter away from

moisture or water.

COOL

Ambient air temperature should be between 30°f (-1°C) non-condensing, and 105°f (40°C). Do not place

the inverter on or near a heating vent or any piece of equipment which is generating heat above room

temperature. Keep the inverter away from direct sunlight, if at all possible.

VENTILATED - BY COOLING FAN(S)

The unit is cooled by 2-speed load controlled fan(s). SSW-350 & 600 have 1 fan and SSW-1000, 1500

& 2000 have 2. The fan(s) will run at lower speed up to certain threshold of power and at full speed

thereafter. Keep the area surrounding the inverter clear to ensure free air circulation around the unit.

Do not place items on or over the inverter during operation. An additional external fan is helpful if the

inverter is operating at maximum power outputs for extended periods of time. The unit will shut down

if the internal temperature of a hot spot exceeds the specified limit. The unit will remain latched in shut

down condition and will require manual reset by switching the unit off and oN again after the unit has

cooled down.

SAFE - Do not use the inverter near flammable materials or in any locations that may accumulate

flammable fumes or gases.