Samlex America SSW-2000-12A Manuel d'utilisation
Page 17

17
Section 9 |
SPeciFicAtionS
MODEL NO. SSW-350-12A SSW-600-12A SSW-1000-12A SSW-1500-12A SSW-2000-12A
INPUT
DC INPUT VOLTAGE RANGE
10.5 - 15.3 VDC (± 0.3 VDC)
DC INPUT CURRENT
AT RATED LOAD
35A
60A
100A
150A
200A
DC INPUT CURRENT
AT NO LOAD
< 0.5A
< 0.7A
< 0.9A
< 1.0A
< 1.1A
OUTPUT
AC OUTPUT VOLTAGE
115 VAC (± 5 VAC)
AC OUTPUT FREQUENCY
60 Hz (± 1Hz)
AC OUTPUT WAVE FORM
PUre SINe WAVe
CONTINUOUS ACTIVE
OUTPUT POWER
350W
600W
1000W
1500W
2000W
MAXIMUM ACTIVE SURGE
POWER (LESS THAN 1 SEC)
700W
1200W
2000W
3000W
4000W
PEAK EFFICIENCY
89%
89%
89%
90%
90%
PORTS
USB CHARGING PORT
(+5 VDC, 500 MA)
YeS
YeS
No
No
No
REMOTE CONTROL PORT
(8 POSITION MODULAR
CONNECTOR)
No
No
YeS
YeS
YeS
PROTECTIONS
LOW INPUT VOLTAGE
WARNING ALARM
11.0 VDC ± 0.3 VDC
LOW INPUT
VOLTAGE SHUTDOWN
10.5 VDC ± 0.3 VDC
HIGH INPUT
VOLTAGE SHUTDOWN
15.3 VDC ± 0.3 VDC
GROUND FAULT/OVERLOAD/
SHORT CIRCUIT SHUTDOWN
YeS
OVER TEMPERATURE
SHUTDOWN
YeS
COOLING
2-SPeeD LoAD CoNTroLLeD fAN (ALWAYS oN)
NUMBER OF COOLING FANS
1
1
2
2
2
INTERNAL BLADE TYPE FUSES,
SOLDERED (MULTIPLE AUTOMO-
TIVE TYPE ATC/ATO IN PARALLEL)
2 x 25A
3 x 30A
6 x 30A
8 x 30A
10 x 30A
CONNECTIONS
INPUT
TerMINALS WITH
THUMb SCreW (M4)
NUT AND boLT (M9)
OUTPUT
2 x NeMA5-15r
NorTH AMerICAN
reCePTACLeS
DUAL NeMA5-20r
NorTH AMerICAN
reCePTACLeS WITH GfCI
SAFETY
COMPLIANCE
LISTeD To UL STANDArD UL-458
GENERAL
OPERATING AMBIENT
TEMPERATURE
0°C to 40°C; 32°f to 104°f
STORAGE TEMPERATURE
-30°C to 70°C; -26°f to 158°f
DIMENSIONS, IN (L X W X H) 7.87 X 6.10
X 2.24
9.06 X 6.10
X 2.24
10.43 X 8.74
X 3.46
12.2 X 8.74
X 3.46
12.2 X 8.74
X 3.46
DIMENSIONS, MM (L X W X H)
200 X 155
X 57
230 X 155
X 57
265 X 222
X 88
310 X 222
X 88
310 X 222
X 88
WEIGHT, KG
0.7
0.9
2.6
3.2
3.8
WEIGHT, LB
1.5
2
5.7
7.1
8.4
ACCESSORIES
INCLUDED
DC INPUT WIRES WITH
BATTERY CLAMPS
3'
AWG #12
3'
AWG #8
No
No
No
REMOTE CONTROL
SSW-R1-12B
No
No
YeS
YeS
YeS