Yokogawa europe b.v, Im 12d7b3-f-e, Spécifications 2-8 – Yokogawa EXA SC202 2-Wire Conductivity Transmitter/Analyzer Manuel d'utilisation

Page 15

Advertising
background image

IM 12D7B3-F-E

Spécifications 2-8

Stamp Company :

Stamp Certification Institute :

Signature :

Remarks : Model EXA SC202S-N

No revision to drawing without prior FM Approval

Title : FM Control Drawing SC202S-N (Non-incendive)

Number : FF1-SC202S-00

Page : 6 of 10

Revision : 2.4

Sen

sor

te

rm

in

al

s

11

-1

6

M

ax

. c

ab

le

le

ng

th

: 6

0 m

tr

.

Ca

ble

d

ia

. :

3

1

2 m

m.

Sen

sor

te

rm

in

al

s

11

-1

6

M

ax

. c

ab

le

le

ng

th

: 6

0 m

tr

.

Ca

bl

e

dia

.:

3

12

mm

n

cla

ss

if

ie

d

Lo

ca

tio

n

+ _

G

C

la

ss

if

ie

d

Lo

ca

tio

n

Un

cl

as

si

fie

d L

oca

tio

n

+ _

G

Pr

ote

cti

ve

ear

th

In

tr

in

si

ca

lly

s

af

e d

es

ig

n

FM

C

la

ss

I

, D

iv

.2

, G

ro

up

A

B

C

D,

T

4

fo

r

amb

ie

nt

te

m

p.

<

5

C

T

6

fo

r

amb

ie

nt

te

mp

. <

40¡

C

E

XA

SC

202

S

ana

lys

er

+

-

L

oa

d

R

esi

sta

nc

e

Cl

ass

if

ie

d

Lo

ca

tio

n

Pr

ote

ct

iv

e

e

ar

th

FM A

pp

ro

ve

d

po

we

r s

upp

ly

Vo

c

¡Ü

3

1.5

V

D

C

Fo

r ele

ctr

ica

l da

ta:

see

tex

t be

lo

w.

Fo

r ele

ctr

ical

data:

se

e

tex

t b

elo

w.

In

tr

in

si

cal

ly

s

af

e d

es

ig

n

FM

C

la

ss

I,

D

iv

.2

, G

ro

up

A

B

C

D,

T

4

f

or

a

mb

ie

nt

tem

p.

<

5

C

T

6

f

or

a

mb

ie

nt

tem

p.

< 4

C

E

XA

SC

20

2S

an

al

yse

r

+

-

FM A

ppr

ov

ed

po

we

r

su

pp

ly

Vo

c

¡Ü

3

1.5

VDC

Electrical data of the EXA SC202S : - Supply circuit (terminals + and -): - Sensor input circuit (terminals 11 through

16):

Maximum input voltage

V

max

= 31.5 V. Maximum output voltage

V

t

= 14.4 V.

Maximum input power Pi = 1.2 W Maximum output current I

t

= 12.8 mA.

Effective internal capacitance

Ci = 22

nF Maximum allowed external capacitance C

a

= 1,4

F.

Effective internal inductance Li = 22

H Maximum allowed external inductance L

a

= 900 mH.

The Hand Held Terminal must be FM Approved in case it is used in the classified location. When installing this equipment, follow the manufacturers installation drawing. Installation shall be in accordance with Article 501.4(B) of the National Electrical Code (ANSI/NFPA 79). Nonincendive field wiring may be installed in accordance with Article 501.4(B)(3)

Grounding shall be in accordance with Article 250 of the National Electrical code

WARNING

-

Substitution of components may impair suitability for Division 2

-

Do not remove or replace while circuit is live unless area is know to be non-hazardous

-

Explosion Hazard — Do not disconnect equipment unless area is know to be non-hazardous

-

Do not reset circuit breaker unless power has been removed from the equipment or the area is know to be non- hazardous

YOKOGAWA

EUROPE

B.V.

Date : 26/07/2004

Advertising