111 information procedure of lamp unit replacement, English – Panasonic PT DW10000U Manuel d'utilisation

Page 111

Advertising
background image

ENGLISH –

111

Information

Procedure of lamp unit replacement

1. Be sure to observe the procedure “Powering up the projector” (p. 35)

and “Powering off the projector” (p. 36), remove the power plug and
confirm that the surroundings of the lamp unit have cooled off.

2. Use a Phillips screwdriver to

loosen the lamp unit cover screw
at the rear of the projector until the
screw turns freely.

3. Open the lamp unit cover and

remove it from the projector.

4. Use a Phillips screwdriver to

loosen the three fixing screws for
the lamp unit to be replaced until
the screws turn freely. Hold the
handle of the lamp unit and gently
pull the lamp unit out from the
projector.

5. Install the new lamp unit.

6. Use a Phillips screwdriver to securely tighten the 3 lamp unit fixing

screws for each lamp unit.

7. Install and close the lamp unit

cover, and then use a Phillips
screwdriver to securely tighten the
lamp unit cover screw.

Caution

Firmly install the lamp unit and lamp unit cover. If not
installed firmly, a protection circuit will function and the
power will not be turned on.

CAUTION

The lamp unit and structural parts around the
lamp unit will be hot immediately after the
projector has been used.
You might get burned if you touch it while it is still
hot.

CAUTION

The lamp unit and structural parts around the
lamp unit will be hot immediately after the
projector has been used.
You might get burned if you touch it while it is still
hot.

Lamp unit cover screw

Lamp unit cover

Lamp unit cover screw

Lamp unit cover

Lamp unit 1

Lamp unit 4

Lamp unit 2

Lamp unit 3

Fixing
screws

Handle