If execution of the command is taking some time

If execution of a command takes some time,
WAIT may be returned as the returned value. In
this case, a value will be returned if you wait a
while. During this time, new commands will not
be received, even if they are sent.

No ID number is attached to WAIT response.
• Cases where WAIT is returned:

- When repeater control is used
- When an IDSL or IDLK command is used
- When one of the following commands is used: RSET, INPS, ASNC, WIDE, EMAG, EPOS, PXSL,

POWR

When control via RS-232C is locked (to prevent use) using the operation lock function (see

page 26)

If the current parameter is read out using “?” for the parameter (for numerical values etc.)

• Response when no ID number has been set

Example:

VOLM????
10

• Response when an ID number has been set (In the example below: ID number = 1)

Example:

VOLM????
10

001

<Communication interval>

• If the next command is sent in the interval before OK or ERR is returned, it will basically be ignored.
• Provide an interval of 100 ms or more between the command response and the transmission of the

next command.

I

W

T

A

Return code

(0D

H

, 0A

H

)

E

C

D

K

O

L

Return code

(0D

H

, 0A

H

)

VOLM0020
OK

INPS0001
WAIT
OK

Interval of 100 ms or more