Pc operation, Continued), Response format in advanced operation – Sharp PN-655U Manuel d'utilisation

Page 46

Advertising
background image

44

E

<Response format in Advanced operation >

When a command has been executed correctly

• Response when no ID number has been set

A response is returned when execution of the
pertinent command is finished.

• Response when an ID number has been set

When a command has not been executed correctly*

• Response when no ID number has been set

• Response when an ID number has been set

* This is returned when there is no such command, or when the command cannot be used in the current state of

the monitor.
Example: When “ADJUSTMENT” is used (a command which is effective when the input mode is “ANALOG”),
while video is displayed (the input mode is “VIDEO”).

* If communication has not been established for reasons like a bad connection between the PC and the monitor,

nothing is returned, not even ERR.

* If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002

is used, but no

monitor with ID number: 2 is found), no response is returned.

O

K

Return code
(0D

H

, 0A

H

)

O

K

SPC

0

0

1

ID number of responding monitor

Space (20

H

)

Return code

(0D

H

, 0A

H

)

R

R

E

Return code

(0D

H

, 0A

H

)

R

R

E

SPC

0

0

1

ID number

Space (20

H

)

Return code

(0D

H

, 0A

H

)

PC Operation