Initialization (Reset)/Functional Restriction Setting

You can return contrast, image quality, and other settings to their factory-preset values, specify whether
power LEDs lights, and enable control via RS-232C (see page 37) among other functions.

1.

After pressing

SIZE

for about 5 seconds, press

,

,

, and

in that order.

The FUNCTION 1 screen will appear.

2.

Select and set the items you want.

3.

Press

MENU

to return to the normal screen.

[ALL RESET]
Function

Resets all settings of the monitor to their factory preset values. After initialization

(reset), turn the main power switch off and then back on.

[ADJUSTMENT LOCK]
Function

Specifies whether to lock settings such as ADJUSTMENT and WHITE BALANCE.

While locked, the remote control unit cannot perform operations other than turning

power on/off (POWER button) and displaying the FUNCTION 1 screen.

Default UNLOCKED
LOCKED

Locks the setting.

UNLOCKED

Unlocks the setting.

[OSD DISPLAY]
Function

Hides/shows menus. The FUNCTION 1 screen cannot be hidden.

Default ON
ON

Displays the menus.

OFF

Hides the menus.

[LED]
Function

Specifies whether to light power LEDs.

Default

ON

ON

Lights power LEDs.

OFF

Does not light power LEDs.

[RS-232C]
Function

Specifies whether to allow control via RS-232C (see page 37).

Default UNLOCKED
LOCKED

Disables control via RS-232C.

UNLOCKED

Enables control via RS-232C.