Warning displays, E 29 f, English – JVC LD-HD2KBE Manuel d'utilisation

Page 29

Advertising
background image

29

Warning Displays

When the internal temperature of the unit is high during operation, a warning message will appear on the LCD.

Message

Description of Warning

Actions

ALEVEL 1 WARNING HIGH
TEMPERATURE

B

Displayed when the internal
temperature of the unit is higher than
during normal operation.

Turn off the power of the unit and
allow the interior to cool down. Upon
doing so, check that the air inlets are
not blocked and start up the basic
operation as usual.

ALEVEL 2 WARNING HIGH
TEMPERATURE

B

Displayed when the internal
temperature of the unit has risen
close to the specified value.

Turn off the power of the unit
immediately and allow the interior to
cool down. Upon doing so, check that
the air inlets are not blocked and start
up the basic operation as usual.

ALEVEL 3 WARNING
EXCESSIVE TEMPERATURE

B

Displayed when the internal
temperature of the unit has risen to
the specified value. The power of
this unit will be turned off
automatically after the warning
message is displayed for 5 seconds.

Pull out the power plug from the outlet
and allow the interior to cool down.
Upon doing so, check that the air
inlets are not blocked and start up the
basic operation as usual.

ENGLISH

LD-HD2KU_E.book Page 29 Thursday, November 17, 2005 4:27 PM