4.3 Plumbing connections:

To connect the dishwasher to the water network make sure that:

There is a “gate valve” that is able to interrupt the water supply when necessary or in case of repair.

A supply pipe has been envisaged for each user in order to avoid any load or pressure drops.

A pressure reducer complete with by-pass has been installed upstream, if the static pressure is greater than

345 kPa (50 psi).

Then connect the filling solenoid valve to the water supply tap using the hose provided.

4.4 Connection to the drainage :


The tank empties by gravity, so the drain must be at a lower level than the

machine base.

Connect the machine drains to the sewer system using pipes that resist a

constant temperature of 80°C.

The drain spigot must be connected to a well or a water trap in the floor by a

flexible pipe drain.


4.5 Limit switch connection:

The table below indicates the requirements and default settings of the dishwasher:



Mount the limit switch (found on the side panel of the machine) on the outfeed

surface.











4.6 Commissioniing (filling the Booster Tank):

It is necessary to carry out the following Booster Tank filling operation during the installation phase.

1)

Energize the machine using the wall-mounted main switch.

The machine emits a beep and displays the uploaded software version, after which some dashes as shown in the
figure appear.