PERFORMANCE DATA SHEET

WATER FILTRATION SYSTEM

MODEL MF-2008-R2 CAPACITY 200 GALLONS (757 LITERS)

System tested and certified by NSF International against

NSF/ANSI Standards 42 and 53 for the reduction of contaminants

specified on the Performance Data Sheet.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction

of the substances listed below. The concentration of the indicated substances in water

entering the system was reduced to a concentration less than or equal to the permissible

limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction Influent challenge

concentration

(mg/L)

Maximum permissible

product water

concentration (mg/L)

Avg %

Reduction

NSF

Reduction

Requirements

Chlorine Reduction

2.0 mg/L

±

10%

NA

93.7%

50%

Particulate

Reduction, Class I*

10000/ml

NA

>99.9%

85%

Lead Reduction

0.15mg/L

±

10%

0.010

99.60%

NA

Live Cysts†

50000/L

NA

>99.99%

99.95%

Test Parameters: pH = 7.69

±

0.5 unless otherwise noted. Flow = 0.52 gpm (1.89 Lpm).

Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).

It is important that operational,

maintenance, and filter replacement

requirements be carried out for the

product to perform as advertised.

Property damage can occur if all

instructions are not followed.

The disposable cartridge must be

changed at least every 6 months.

Use replacement filter MF-2008-R2.

The filter monitor system measures the

amount of water that passes through

the filter and alerts you when it is time

to replace the filter. See “Using the

Controls.”

After changing the water filter, flush the

water system. See “Dispenser.”

These contaminants are not necessarily

in your water supply. While testing was

performed under standard laboratory

conditions, actual performance may

vary.

The product is for cold water use only.

The water system must be installed in

compliance with state and local laws

and regulations.

Do not use with water that is

microbiologically unsafe or of unknown

quality without adequate disinfection

before or after the system. Systems

certified for cyst reduction may be used

on disinfected waters that may contain

filterable cysts. EPA Est. No. 10350-MN-

005.

Refer to the “Warranty” section for the

Manufacturer’s limited warranty, name

and telephone number.

Application Guidelines/
Water Supply Parameters

Water Supply

Potable City or Well

Water Pressure

35 - 120 psi

(241 - 827 kPa)

Water

Temperature

33° - 100°F

(1° - 38°C)

Service Flow

Rate

0.52 gpm (1.89 L/min.)

@ 60 psi

* Class I particle size: >0.5 to <1

µ

m.

† Based on the use of Cryptosporidium parvum

oocysts.

® NSF is a registered trademark of NSF

International.