INSTALLATION

LOCATION

A) This room air conditioner is designed to fit

easily into a single or double hung window.

However, since window designs vary, it may be

necessary to make some modifications for safe,

proper installation.

B) Make sure window and frame are structurally

sound and free from dry and rotted wood.

C) For maximum efficiency, install the air

conditioner on a side of the house or building

which favours more shade than sunlight. If the unit

is in direct sunlight, it is advisable to provide an

awning over the unit.

D) Provide sufficient clearance around the cabinet

to allow for ample air circulation through the unit

(See Fig. 2). The rear of the unit should be

outdoors and not in a garage nor inside a building.

Keep unit as far away as possible from

obstacles/obstructions and at least 30” above

the floor or ground. Curtains and other objects

within a room should be prevented from

blocking the air flow.

E) Be certain the proper electrical outlet is

within reach of the installation. Use only a

single outlet circuit rated at 15 amps. All wiring

should be in accordance with local and

national electrical codes.

TOOLS NEEDED FOR INSTALLATION:

Screw Drivers: Both Phillips and flat head

Power Drill: 1/8 inch diameter drill bit

Pencil

Scissors

Measuring Tape

Carpenters Level

ELECTRIC SHOCK HAZARD: To avoid the possibility of personal injury, disconnect power to

the unit before installing or servicing.

3/4” screws (9)

3/8” screws (4)

Safety Lock (1)

Adhesive

Foam Seal (1)

Frame Lock

(2)

Regular Foam

Seal (1)

Side Curtain RH (1)

Side Curtain LH (1)

Fig. 1

INSTALLATION HARDWARE

Your Room Air Conditioner is designed for easy

installtion in a single or double-hung window. This unit

is NOT designed for vertical (slider type) windows

and/or through-the-wall applications.

NOTE: Save the shipping carton and packing materials

for future storage or transport of the unit. From carton,

remove the plastic bag containing the installation

hardware kit necessary for the installation of your air

conditioner. Please check the contents of hardware kit

against the corresponding model check list, prior to

installation of the unit. See Fig. 1.

CAUTION: Because the compressor is located on

the controls side of the unit (left side), this side will be

heavier and more awkward to manipulate. Inadequate

support on control side of the unit can result in personal

injury and damage to your unit and property. Therefore, it

is recommended that you have someone assist you during

the installation of this unit.

F) DO NOT install unit where leakage of

combustible gas is suspected. Your air

conditioner may fail to operate in air containing

oils (including machine oils), sulfide gas, near

hot springs, etc.

Awning

Fence,
wall, or
other
obstacle

Ground

Side

Obstruction

20”

Min

30”

Min

20”

Min

12” Min

Fig. 2

Your unit is designed to evaporate condensation
under normal conditions. However, under extreme
humidity conditions, excess condensation may
cause basepan to overflow to the outside. The unit
should be installed where condensation run-off
cannot drip on pedestrains or neighboring properties