READ ALL SAFETY INFORMATION BEFORE USING

1) All wiring must comply with local and
national electrical codes and must be installed
by a qualified electrician. If you have any
questions regarding the following instructions,
contact a qualified electrician.
2) Check available power supply and resolve
any wiring problems BEFORE installing and
operating this unit.
3) This 115V air conditioner uses 10.0 or less
nameplate amps and may be used in any
properly wired, general purpose household
receptacle. See Table 1 for specifications for
individual branch circuit.
4) For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a qualified electrician.
5) The wall outlet must match the 3-prong plug
on the service cord supplied with the unit. DO
NOT use plug adapters. See Table 2 for
receptacle and fuse information. If it is
necessary to use an extension cord to connect
your air conditioner, use an approved “air
conditioner” extension cord only
(available
at most local hardware stores).
6) The rating plate on the unit contains
electrical and other technical data. The rating
plate is located on the right side of the unit,
above the power cord.

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

5.0 to 10

18

AWG- American Wire Gauge

*Based on copper wire at 60°C temperature rating.

TABLE 2

Receptacle and Fuse Types

Rated Volts

120

Amps

10

Wall Outlet

Fuse Size

15

Time Delay Fuse

Plug Type

(or Circuit Breaker)

3

PART IDENTIFICATION

IMPORTANT SAFETY INFORMATION

ELECTRICAL

SPECIFICATIONS

Air FIlter

Exterior Air

Inlet

Cabinet

Interior Air Inlet

Control Panel

Interior Air Inlet