DRAIN PUMP

6

The Marvel Drain Pump is designed to remove drain water

from ice machines installed in areas without direct drainage

access. The sealed reservoir pump collects the melted ice water

and pumps it to a maximum lift of eight (8) feet (2.44 meters)

through 3/8” I.D. vinyl tubing to a drain.

This pump has been evaluated for use with water only.

NOTE: Reasonable care and safe methods should be practiced.

Do NOT work with energized electrical equipment in a wet area.

Read and follow the installation instructions listed in this manual.

Risk of electric shock - This pump is supplied with a grounding

conductor and grounding-type attachment plug. To reduce the

risk of electric shock, be certain that it is connected only to prop-

erly grounded, grounding-type receptacle.

Maintenance

The following items require review on a regular basis.

1. Check that the vent line is open, free of kinks/sharp bends,

so that air flows freely from the pump reservoir.

2. Check that the discharge tubing is free of foreign material

(algae, etc.) and kinks/bends. Confirm that the check valve

is operational by observing that the water flow is evident in

one (1) direction only - out of the pump. Remove and clean

as required.

Figure 7

Drain

Access

Access

panel

Ice Machine

63/4”

(17.1cm)

83/8”

(21.3cm)

18”

(45.7cm)

143/4”

(37.5cm)

23/8” (6.0cm)

41/16”

(10.3cm)

9/16” (1.4cm)

211/2”

(54.9cm)

Figure 6

Figure 5

Access

panel

11/2” Drain pipe

Advertising