DRAIN PUMP REMOVAL INSTRUCTIONS

24

Figure 26

Unscrew the leveling leg so the

end of the threads is flush with

the top of the nut insert.

Remove these 4 hose clamps, then re-

move the 3 tubes from the drain pump

It may be necessary to disconnect this

electrical connection on factory installed

drain pumps

Drain pump

ground wire

connection

Drain Pump Removal Instructions:

1. Unplug ice machine from the electrical supply and remove

the rear access cover from the ice machine. (See page 5 for

instructions).

2. Unscrew the leveling leg in the back corner until the end of

the threaded portion is flush with the threaded nut insert in

the base. (see Figure 26 ).

3. Unscrew the 4 hose clamps and remove the 3 hoses from

the front of the drain pump. (See Figure 26).

4. Rotate the drain pump and remove from the ice machine,

(See Figure 25). It may be necessary to disconnect the

ground wire connection in the back flange of the cabinet.

(See Figure 26).

5. Disconnect the ice machine power cord from the drain

pump (See Figure 27).

6. To drain water from the pump follow step 14 and 15 on

page 23.

7. Installation of drain pump is reverse of this procedure.

Figure 25

Rotate drain pump

and remove from

back of ice machine.

Drain valve

Advertising