DRAIN PUMP REMOVAL INSTRUCTIONS

25

Figure 27

Ice machine

power cord

Additional issues to be inspected by the installer

upon service replacement:

1) The drain pump must be level.

2) No pinched water lines.

3) No interference with electrical cords or wiring.

4) The drain pump should not set on any obstacles, wiring, etc.

5) Secure all hose clamps leading to and from the drain pump.

6) Insure that the vent tube height is adequate - 18 inch mini -

mum.

7) Insure that drain height is adequate - maximum of 8 foot.

8) Insure that drain length is adequate - maximum of 20 foot.

9) Checked for water leaks after installation of the drain pump.

10) Check for vibrations caused by improper installation.

11) Insure that there is no interference with back access cover.

12) Insure that the hole grommets are in place at each location

so that any vent or drain tubes do not rub on any sharp

surfaces.