Gas Connection

The 1" NPT inlet at the rear must be considered in piping the

gas supply for double stack units or ¾" NPT for individual (or

single deck) connections. Undersized gas supply line(s) may

restrict the gas supply and affect performance. If other gas

appliances are supplied by the same supply line, the supply

line must be sized to carry the combined volume without

causing more than 1/2" pressure drop at the manifold of each

appliance on the line at full rate.

Recommended supply pressures are 7" WC, (NAT), and

11" WC, (PRO); ± 5%. (Must not exceed 13.8" WC [NAT], and

15" WC [PRO]).

Electrical Connection

A 15 AMP service must be provided for each oven. For 115

VAC usage, a cord and plug (NEMA #5-15P) is provided but

connection to the electrical service must be electrically

grounded in accordance with local codes, or in the absence of

local codes, with the National Electrical Code, ANSI/NFPA 70,

or the Canadian Electrical Code, CSA C22.2, as applicable.

This appliance is equipped with a three-prong (grounding)

plug for your protection against shock hazard and should

be plugged directly into a properly grounded three-prong

receptacle.

DO NOT CUT OR REMOVE THE

GROUNDING PRONG FROM THIS PLUG.

A wire diagram is affixed to the rear of the unit.

Ventilation & Air Supply

Proper ventilation is highly important for good operation.

There are only two choices for properly venting an oven: 1)

canopy hood style or 2) direct venting. The ideal method

of venting a GAS Convection Oven is through the use of a

properly designed canopy, which should extend 6" (150 mm),

beyond all sides of the appliance and 6'6" (1950 mm) from the

floor.

A strong exhaust fan will create a vacuum in the room. For an

exhaust system vent to work properly, exhaust and make-up

air must be balanced properly. For proper air balance contact

your local H.V.A.C. contractor.

All gas burners and pilots need sufficient air to operate and

large objects should not be placed in front of this oven, which

would obstruct the airflow through the front. Installation Of A

Direct Flue

INSTALLATION Continued

When the installation of a canopy type exhaust hood is

impossible the oven may be direct vented. Before direct

venting check your local codes on ventilation, in the absence

of local codes, refer to the National Fuel Code NFPA 54, ANSI

Z223.1 (latest revision).

If the unit is to be connected directly to a direct flue, it is

necessary that draft diverter be installed to insure proper

ventilation.

DRAFT DIVERTER

Direct venting, should be positioned on the main top and

fastened with sheet metal screws provided.

NOTE: Each oven has been factory tested and adjusted prior

to shipment. It may be necessary to further adjust the oven

as part of a proper installation. Such adjustments are the

responsibility of the installer. Adjustments are not considered

defects in material and workmanship, and they are not

covered under the original equipment warranty.

DO NOT UNDER SIZE VENT PIPE!

This can cause resistance to flow and impede good venting.

We suggest that if a horizontal run must be used it should

rise no less than 1/4" (6.25mm) for each linear foot of run, and

after a total of 180° of bends you should increase the size of

stove pipe by two (2") inches. The flue should rise 2' (60cm) to

3' (90cm) above the roofline or 2' (60cm) to 3' (90cm) above

any portion of a building within a horizontal distance of 10

(3 meters) feet.

The following diagram is only one example from the National

Fuel Gas Code Book NFPA 54, ANSI Z223.1, 7.5.3: