Installation Of Double Deck Models

A. Position insert in bottom leg opening and tap insert up

into leg till it seats at collar. Attach six inch (6") legs to

lower oven section. Raise unit or lay on its left side. Place

the front legs on the oven so as to line up with four (4)

attaching bolt holes. Secure leg to oven frame using (4)

3/8-16 x 3/4 bolts and washers provided. Repeat at rear of

unit.

B. Remove lower front cover of top deck (located under oven

doors). Raise top deck into place and line up body sides

and back of the unit. Fasten the rear of the units together,

with the stacking bracket, using (6) 1/4-20 machine

screws, lock washers and nuts, (provided).

C. Install the interconnecting flue parts, carefully following

the instructions contained in the stacking kit. Pay

particular attention to the type of ovens you are stacking

and be sure to follow the corresponding instructions.

D. Assemble the stacking pipes provided in the stacking

kit as shown in the diagram at the top of this page. This

allows both ovens to be supplied by a single gas line. The

minimum recommended size of a single supply line for

two stacked ovens is 1 inch. Use a pipe thread compound

that is intended for use on propane gas piping and be sure

to check for leaks before finalizing the installation.

E. Check leveling of unit four (4) ways (using a common

carpenter's level on the rack inside the oven).

F. Plug the cord set of each unit into a 115-Volt power supply

outlet.

G. Maintain clearance from combustibles.

Each gas appliance shall be located with respect to building

construction and other equipment so as to permit access to

the appliance. Such access and clearance may be necessary

for servicing and cleaning.

INSTALLATION Continued

90 Degrees Street Elbow

90 Degrees Street Elbow

20 1/2" Nipple

3/4" to 1"

Bell Reducer

3" Nipple

3" Nipple

3/4" Union

CAUTION:

DISCONNECT BOTH UNITS FROM

ELECTRICAL SUPPLY BEFORE SERVICING.

POWER FAILURE

In the event of a power failure, no attempt

should be made to operate this oven.

IMPORTANT

All gas burners and pilots need sufficient air

to operate and large objects should not be

placed in front of this oven, which would

obstruct the airflow through the front.

Objects should not be placed on main top

rear of oven while in use. This could obstruct

the venting system of the unit's flue products.

Advertising