Part # 1955200 Rev.6 (07/03/12)

Gas Input ratings shown here are for installations up to 2,000-ft. (610m) above sea level. Specify altitudes over 2,000 ft.

Commercial cooking equipment requires an adequate ventilation system. For additional information, refer to the National Fire

Protection Association’s standard NFPA96, “Vapor Removal from Cooking Equipment.” (NOTE: For North America only)

Please specify gas type when ordering.

7-3/4"

[197mm]

38-1/4"

[972mm]

3/4"

[19mm]

17-3/4"

[451mm]

TOP VIEW

2"

[51mm]

FLUE: 2-3/8" x 5"

[60mm x 127mm]

3/4" N.PT.

GAS INLET

11-1/2"

[292mm]

38"

[965mm]

32-1/8"

[816mm]

25-3/8"

[645mm]

SINGLE DECK

FR ONT VIEW

1-1/4"

[32mm]

34"

[864mm]

54-9/16"

[1386mm]

3/4" REAR

GAS INLET

32-1/8"

[816mm]

32-1/8"

[816mm]

6-1/4"

[159mm]

14-3/4"

[375mm]

32-1/8"

[816mm]

35-7/16”

[900mm]

32-1/8"

[816mm]

1-1/4"

[32mm]

DOUBLE DECK

FR ONT VIEW

D

H

H

1" REAR

GAS INLET

Single-Deck

Models

Int. Dimensions :In (mm)

Ext. Dimensions: In (mm)

Ship Wt

Ship Dim.

W

H

D

W

H *

D

Lbs/kg

Cubic Ft.

Standard Depth 29 (736) 24 (610) 24 (610) 38 (965) 57-1/2 (1461) 41-1/4(1048)

515/230

64

Deep Depth

29 (736) 24 (610) 28 (711) 38 (965) 57-1/2 (1461) 44-1/2(1130)

545/245

64

Double-Deck

Models

Int. Dimensions: In (mm)

Ext. Dimensions: In (mm)

Ship Wt.

Ship Dim.

W

H

D

W

H *

D

2@Lbs/kg Cubic Ft.

Standard Depth 29 (736) 24 (610) 24 (610) 38 (965) 70-1/2 (1791) 41-1/4(1048)

1030/465

128

Deep Depth

29 (736) 24 (610) 28 (711) 38 (965) 70-1/2 (1791) 44-1/2(1130)

1090/490

128

*Height with or without standard casters. Height with low profile casters (double deck) is 68-1/2" (1740mm).

Models

Input Ratings, Nat & Pro

Electrical Specifications

BTU/hr

kW Equiv.

Gas Inlet

120V/1Ph.

240V/1Ph.

Single Deck

60,000

17. 6

(1 )@ 3/4" NPT

(1)@9.8A

(1)@ 5.2A

Double Deck

120,000

35.2

(1 )@1" NPT

(2)@9.8A

(2)@ 5.2A

Installation Notes:

Combustable Wall Clear-

ances:

Sides: 1" (25mm)

Back: 3" (76mm)
Entry Clearance:

Crated: 47" (1194mm)

Uncrated: 32-1/2" (826mm)

Operating Pressure:

Natural: 4." WC (10 mbar)

Propane: 10" WC (25 mbar)

Max 13.8" WC @ 70°F (21°C)
NOTE: Data applies only to

North America

Notes:

1. Standard electrical specifications include motor requirements.

2. (120V units) 115V 3/4 HP, 2-speed motor; 1140 and 1725 rpm 60Hz

3. (240V units) 200-240V, 3/4 HP, 2-speed motor; 1140 and 1725 rpm, 60Hz

4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.