Changing the floor tool blades – NaceCare Solutions ETB1120 Manuel d'utilisation

Page 15

Advertising
background image

15

!

!

ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY

MAINTENANCE

Note:

The blades are designed to be reversible, thus extending their useful working life.

Changing the Floor Tool Blades

The floor-tool

Fig.39

Fig.38

To clean the floor-tool, remove securing-pin and disconnect the lifting strap and remove the floor tool securing pin

pull-free the floor tool from the rear of the machine.

Rinse the floor-tool assembly with clean water and refit.

Periodically the floor-tool blades should be examined and checked for wear and damage.

The blade removal is easy. Simply start by removing the four retaining pins (see Fig 38), turn the floor-tool over and

separate the blade carrier from the body (see Fig 39).Peel away the blades from their locating lugs (see Fig 40) and

examine or renew as required.

Replacement is a reversal of the removal process.

Floor-tool overview

1. Floor-tool main body
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Retaining pins x 4

1

2

3

4

5

The ETB range is provided with the Eco Range floor tool.

Fig.40

Advertising