2.2 GENERAL

INFORMATION

THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.

!

WARNING

2.3 MINIMUM APPLIANCE SIZE

Do not install the gas log set into a cavity smaller than that
referenced in the table.

LOG SET

HEIGHT

WIDTH

DEPTH

GL18

18”

22”

14”

GL24

20”

28”

14”

GL30

22”

34”

14”

GL18

GL24

GL30

NG

LP

NG

LP

NG

LP

Altitude (FT)

0-4,500

0-4,500

0-4,500

0-4,500

0-4,500

0-4,500

Max input (BTU/HR)

55,000

55,000

60,000

60,000

65,000

65,000

Min Inlet Gas Supply Pressure

4.5“ Water

Column

11“ Water

Column

4.5“ Water

Column

11“ Water

Column

4.5“ Water

Column

11“ Water

Column

Max Inlet Gas Supply Pressure

7“ Water

Column

13“ Water

Column

7“ Water

Column

13“ Water

Column

7“ Water

Column

13“ Water

Column

Manifold Pressure (Under Flow
Conditions)

3.5“ Water

Column

10“ Water

Column

3.5“ Water

Column

10“ Water

Column

3.5“ Water

Column

10“ Water

Column

2.4 RATING

PLATE

THE RATING PLATE IS CHAINED TO THE LEG OF THE BURNER BASE AND SHOULD BE TUCKED
UNDER THE ENTIRE ASSEMBLY

SAMPLE

This rating plate illustration is for reference only. Refer to the rating plate on the appliance for accurate
information.

W385-1870

SERIAL NUMBER/NO. DE SERIE:

GLE

REFERENCE # W/N 15987

CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: ANSI Z21.60b-2004 CGA 2.26b-2004, DECORATIVE APPLIANCE FOR INSTALLATION IN SOLID-FUEL BURNING APPLIANCES

WOLF STEEL LTD.

24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
WOLF STEEL USA
103 Miller Drive, Crittenden, Kentucky, USA, 41030

18”

20”

22”

GL18 PE

GL24 PE

GL30 PE

GL18 NE

GL24 NE

GL30 NE

C E R T I F I E D

CERTIFIED FOR CANADA/ USA

CERTIFIEE POUR

CANADA/ USA

55,000BTU/h 60,000BTU/h 65,000BTU/h
34,000BTU/h 35,000BTU/h 36,000BTU/h

55,000BTU/h 60,000BTU/h 65,000BTU/h
45,000BTU/h 50,000BTU/h 50,000BTU/h