Warning, Maintenance, 0 maintenance – Napoleon Fireplaces FIBERGLOW GL18E Manuel d'utilisation

Page 15

Advertising
background image

15

W415-1071 / C / 01.11.12

7.3 FLAME

CHARACTERISTICS

It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustrations provided. If any fl ames appear abnormal call a service person.

FLAME MUST ENVELOP
UPPER 3/8” TO 1/2” OF
FLAME SENSOR

PILOT

BURNER

ELECTRODE

FLAME

SENSOR

54.1A

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing. This appliance and its venting system should
be inspected before use and at least annually by a qualifi ed service person. The appliance area must be
kept clear and free of combustible materials, gasoline or other fl ammable vapours and liquids. The fl ow of
combustion and ventilation air must not be obstructed.
1.

In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to
expose both assemblies.

2.

Keep the control compartment, media, burner, air shutter opening and the area surrounding the
appliance clean by vacuuming or brushing, at least once a year.

3.

Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or
are not burning properly.

4.

Check to see that the pilot fl ame is large enough to engulf the fl ame sensor and/or thermocouple /
thermopile as well as reaches the burner.

5.

Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning
which can be distributed in the surrounding living area.

6.

Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10
second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer /
distributor.

7.

Visually inspect the appliance for carbon build up. Using a small whisk or brush, brush off the carbon
and vacuum up or sweep into garbage.

8.

Check to see that the appliance is venting correctly. Ensure chimney system is safe and unobstructed.

40.19

MAINTENANCE

MAINTENANCE

MAINTENANCE

TURN OFF THE GAS AND REMOVE BATTERIES BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

!

WARNING

8.0 MAINTENANCE

Advertising
Ce manuel est liée aux produits suivants: