Warning – Napoleon Fireplaces GDI30G Manuel d'utilisation

Page 19

Advertising
background image

19

W415-0832 / C / 06.07.12

This appliance has an air shutter that
has been factory set open according
to the chart below:

Closing the air shutter will cause a
more yellow fl ame, but can lead to
carboning. Opening the air shutter will cause a more blue
fl ame, but can cause fl ame lifting from the burner ports. The
fl ame may not appear yellow immediately; allow 15 to 30
minutes for the fi nal fl ame color to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER!
Access plate and gasket must be re-installed after adjustment.

The alternate access is to remove the glass media, media tray and burner from the appliance and then adjust the
air shutter. NOTE: When removing the media tray make sure the glass media are away from the center of
the screen, exposing the burner, before lifting media tray out.

When replacing burner, absolutely no glass can be in cup surrounding the orifi ce. HINT: If glass falls into cup and
surrounds the orifi ce, insert a clean bag into a vacuum cleaner and vacuum out glass media. Replacement glass
media can be ordered from Wolf Steel Ltd.

9.2 VENTURI

ADJUSTMENT

AIR SHUTTER

ACCESS PLATE

THE FRONT OF THE APPLIANCE BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE

COOL COMPLETELY BEFORE CONDUCTING SERVICE.

!

WARNING

NG

LP

GDI-30G

0

1/4"

9.3 FLAME

CHARACTERISTICS

It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.

FLAME MUST ENVELOP
UPPER 3/8” TO 1/2” OF
FLAME SENSOR

PILOT

BURNER

ELECTRODE

FLAME

SENSOR

54.1A

Advertising