4.0 FRAMING

Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed. These same requirements apply to any combustibles protruding on either side of the
appliance.

3

8

5

4

MANTEL DEPTH

0

+

(

,

*

+

7

0

$

1

7

(

/

6

11

9

10

12

4.1 MINIMUM MANTEL CLEARANCES

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

This insert must be recessed into a vented noncombustible wood-burning appliance (prefabricated or masonry)
only. The minimum appliance opening size in which the appliance is to be installed is:

HEIGHT 22" WIDTH 28" DEPTH 18"
The minimum allowable chimney fl ue size is 6" round.

The minimum distance, from the bottom of a combustible mantel projecting 3" maximum from the wall to the
top of the front, is 8".

MINIMUM CLEARANCE TO COMBUSTIBLES MUST BE MAINTAINED OR A SERIOUS FIRE HAZARD

COULD RESULT.

NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.

!

WARNING

6” MANTEL

5”

3”

4”

9”

8”

10”

11”

25 ½”