Warning, 0 replacement blower installation – Napoleon Fireplaces GDI30G Manuel d'utilisation

Page 14

Advertising
background image

14

W415-0832 / C / 06.07.12

6.0 REPLACEMENT BLOWER INSTALLATION

A.

Turn off the electrical power and the gas supply to the
appliance insert.

B.

Open the glass door, see "DOOR REMOVAL AND
INSTALLATION" section. Remove the glass media and
media tray, see "MEDIA TRAY INSTALLATION" section.

C.

Remove the two side porcelain panels by removing the four
screws located at the front of the appliance then remove the
back porcelain panel.

D.

Remove the front blower access cover held on with 4
screws.

E.

Remove the rear blower access cover. NOTE: Check
the blower gasket for damage. Replace if damaged.

F.

Disconnect the two blower wires. Remove the blower
from the mounting plate and replace. For thermal switch
replacement: Remove the mounting bracket secured to
the underside of the burner base. Remove the thermal
switch from the bracket and replace.

G.

Reconnect the two wires. Re-install the blower gasket.
Reattach the blower mounting plate and blower access
covers. Replace the glass media. Close the glass door.

H.

Turn the gas supply and electricity back on. Because
the blower is thermally activated, when turned on, it
will automatically start approximately 5-15 minutes
after lighting the appliance insert and will run for
approximately 30-45 minutes after the appliance
insert has been turned off. Use of the fan increases
the output of heat.

Drywall dust will penetrate into the blower
bearings causing irreparable damage and must be
prevented from coming into contact with the blower
or its compartment. Any damage resulting from this
condition is not covered by the warranty policy.

FRONT BLOWER ACCESS

COVER

REAR BLOWER ACCESS

COVER

THERMAL SWITCH /

BRACKET ASSEMBLY

!

WARNING

RISK OF FIRE AND ELECTRICAL SHOCK.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH

THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS

COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL

VOID THE WARRANTY AND CERTIFICATION.

ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE

APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER

CORD BENEATH THE APPLIANCE.

THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN

INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING

CONTACT WITH MOVING OR HOT OBJECTS.

51.5

black

white

red

SPEED
CONTROL
SWITCH

BLOWER

THERMAL
SWITCH

Advertising