Warning – Napoleon Fireplaces 1600C-1 Manuel d'utilisation

Page 10

Advertising
background image

W415-0721 / B / 05.03.11

10

4.1 CHIMNEY

!

WARNING

NEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE.

THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TO

COMBUSTIBLE CHASE MATERIALS TO CAUSE FIRE.

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY SYSTEM SERVING ANOTHER APPLIANCE.

TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDING

THE PROVISIONS OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE.

TO PROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE

WEATHER, WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST RESISTANT PAINT.

DO NOT FILL ANY FRAMED SPACE AROUND THE CHIMNEY WITH INSULATION OR ANY OTHER

MATERIAL INSULATION PLACED IN THIS AREA COULD CAUSE ADJACENT COMBUSTIBLES TO

OVERHEAT.

MAINTAIN A MINIMUM 2” AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM AT ALL

TIMES. FAILURE TO MAINTAIN THIS 2” AIR CLEARANCE WILL CAUSE A STRUCTURE FIRE. NEVER

FILL THIS SPACE WITH ANY TYPE OF MATERIAL.

DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR AND

TERMINATION CAP ARE PACKAGED WITH THESE PARTS.

DO NOT CUT RAFTERS OR CEILING JOISTS WITHOUT FIRST CONSULTING A BUILDING OFFICIAL

TO ENSURE STRUCTURAL INTEGRITY IS NOT COMPROMISED.

FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOOR

AREA.

THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT

ABOVE THE STOVE. ALL HORIZONTAL SMOKE PIPE MUST SLOPE SLIGHTLY UPWARDS A

MINIMUM OF 1/4” PER FOOT AND ALL CONNECTIONS MUST BE TIGHT AND SECURED BY THREE

SHEET METAL SCREWS EQUALLY SPACED. AN UNINSULATED SMOKE PIPE SHALL NOT PASS

THROUGH AN ATTIC, ROOF SPACE, CLOSET, OR SIMILAR CONCEALED SPACE, OR THROUGH A

FLOOR, CEILING, WALL OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTION.

DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION.

63.8

Your appliance may be hooked up with a factory built or masonry chimney. If you are using a factory built
chimney, it must comply with ULCS629 (Canada) or UL103 (USA) standards. It must therefore be a 6" HT Type
(2100°F) chimney. It is extremely important that it be installed according to the manufacturer's specifi cations.
The manufacturer's installation instructions and specifi ed clearances should always be followed in accordance
with local and national codes. In Canada the CSA B365 and the CSA C22.1 installation codes are to be fol-
lowed. In the USA the ANSI NFPA 70 and ANSI NFPA 211 installation codes are to be followed.

Chimney and chimney connector must be in good condition and kept clean.