Napoleon Fireplaces Ascent Multi-View - BHD4 Manuel d'utilisation

Page 7

Advertising
background image

W415-1285 / 04.14.14

7

EN

2.3 GENERAL

INFORMATION

When the appliance is installed at elevations above 4,500 ft (1372m), and in the absence of specifi c

recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be

reduced at the rate of 4% for each additional 1,000 ft (305m).

This appliance is approved for bathroom, bedroom and bed-sitting room

installations and is suitable for mobile home installation.

No external electricity (110 volts or 24 volts) is required for the gas system

operation. Expansion / contraction noises during heating up and cooling

down cycles are normal and are to be expected.

If utilizing one of Wolf Steel's trim or surround kits, follow the framing

instructions and the fi nishing instructions, for removal of the top extension.

NOTE: The protective wrap on plated parts is best removed when the assembly is at room temperature
but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.

67.9%

BHD4

NG

LP

Altitude (FT)

0-4,500

0-4500

Max. Input (BTU/HR)

30,000

30,000

Max. Output Steady State (BTU/HR)

23,000

23,000

Min. Inlet Gas Supply Pressure

4.5" (11mb)

Water Column

11" (27mb)

Water Column

Max. Inlet Gas Supply Pressure

7" (17mb)

Water Column

13" (32mb)

Water Column

Manifold Pressure (Under Flow Conditions)

3.5" (9mb)

Water Column

10" (25mb)

Water Column

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!