W415-0434 / G / 08.08.11

This appliance comes equipped with a
blower, a heat sensor, variable on/off
speed control and a power cord.

The blower is thermally activated, so when
it is turned on, it will automatically start
approximately 15 minutes after lighting the
appliance and will run for approximately
30 minutes after the appliance has been
turned off. Use of the fan increases
the output of heat. Air, drawn in through
the lower louvre access door, is driven
up the back of the fi rebox, and exhaust-
ed as hot air between the upper louvres.

A.

Open the lower control area.

B.

Remove the control panel (3
screws).

C.

Unplug the blower from the junction box or turn off the power to the appliance if hard wired.

D.

Undo the fastener at the left side of the blower mounting plate. The blower should now slide to the left,
away from the mounting tab.

E.

Finally, disconnect the slip-on connectors at the motor of the blower.

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to pre-
vent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy.

10.3 BLOWER REPLACEMENT

!

WARNING

RISK OF FIRE AND ELECTRICAL SHOCK.

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH

THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS

COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL

VOID THE WARRANTY AND CERTIFICATION.

ENSURE THAT THE FAN’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE

APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER

CORD BENEATH THE APPLIANCE.

THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS. WHEN

INSTALLED, ENSURE THAT ANY EXCESS WIRE IS CONTAINED, PREVENTING IT FROM MAKING

CONTACT WITH MOVING OR HOT OBJECTS.

51.5

VARIABLE SPEED SWITCH

G

B

W

HEAT SENSOR

FAN

BLOWER REPLACEMENT

C

A

B

10.4 CARE OF GLASS

5.1

DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.

Buff lightly with a clean dry soft cloth. Clean both sides
of the glass after the fi rst 10 hours of operation with a
recommended fi replace glass cleaner. Thereafter clean
as required. If the glass is not kept clean permanent
discoloration and / or blemishes may result.

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

!

WARNING