Napoleon Fireplaces STARfire 70 - GD70 Manuel d'utilisation

Page 22

Advertising
background image

22

W415-0434 / G / 08.08.11

4.2.3 APPLIANCE VENT CONNECTION

A.

Install the inner fl ex pipe to the appliance. Secure with 3 screws
and fl at washers. Seal the joint and screw holes using the high
temperature sealant W573-0007 (not supplied).

B.

Install the outer fl ex pipe to the appliance. Attach and seal
the joints using the high temperature sealant W573-0002 (not
supplied).

28.1

2” OVERLAP

HIGH TEMP
SEALANT

#8 X 1/2”

SELF

DRILLING

SCREWS

4.3 USING RIGID VENT COMPONENTS

The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf
Steel Ltd. support ring assembly or equivalent noncombustible strapping to maintain the minimum clearance to
combustibles for both vertical and horizontal runs.

All inner exhaust and outer intake vent pipe joints may be sealed using either red high temperature silicone
sealant W573-0002 (not supplied) or black high temperature sealant W573-0007 Mill Pac (not supplied) with
the exception of the appliance exhaust fl ue collar which must be sealed using Mill Pac.

25.1

4.3.1 HORIZONTAL AIR TERMINAL INSTALLATION

A.

Move

the

fi replace into position. Measure the vent length

required between terminal and fi replace taking into
account the additional length needed for the fi nished
wall surface and any 1¼” overlaps between venting
components.

B.

Apply high temperature sealant W573-0007 (not
supplied) to the outer edge of the inner collar of the
fi replace. Attach the fi rst inner rigid pipe component
and secure using 3 self tapping screws. Repeat using the
outer rigid pipe.

C.

Insert the vent pipes through the fi restop maintaining the required clearance to combustibles. Holding
the air terminal (lettering in an upright, readable position), secure to the exterior wall and make
weather tight by sealing with caulking (not supplied).

The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the
depth of its return fl ange.

26.2

SEALANT

HI-TEMP

OUTER

PIPE

INNER

PIPE

CAULKING

2" OVERLAP

SCREWS

#10 x 2½"