Warning, 3 minimum clearance to combustible enclosures, 4 minimum mantel clearances – Napoleon Fireplaces STARfire 70 - GD70 Manuel d'utilisation

Page 29

Advertising
background image

29

W415-0434 / G / 08.08.11

Combustible mantel clearance can vary according to the mantel depth. Use
the graph to help evaluate the clearance needed.

When using the optional ornamental facia and panels, the minimum height
from the top of the appliance to the mantel is 7”

!

WARNING

RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE

TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO

OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE

CLEARLY MAINTAINED.

WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE

HEAT RESISTANT TO PREVENT DISCOLOURATION.

73.1

5.3 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

COMBUSTIBLE

MATERIAL

NONCOMBUSTIBLE
MATERIAL

2" GAP FROM VENTING

19 1/2" MINIMUM

TOP OF UNIT

1" GAP FROM INSULATION SLEEVE

FIRESTOP SPACER

STEEL

HEADER

STAND OFF
SPACER

4 3/8"

SLEEVE

INSULATION

36” TO BASE

OF APPLIANCE

TOP OF

FIREPLACE

9” MANTEL

7”

5”

3”

9”

7”

5”

3”

36”

MANTEL WIDTH

+

(

,

*

+

7

0

$

1

7

(

/

5.4 MINIMUM MANTEL CLEARANCES